Chapter 3 - Robot Installation
38 AdeptSix 300CR Robot Instruction Handbook, Rev. A
Figure 3-3. Installing Cover Bolts
3.5 Types of Mounting
The robot can be mounted in three different ways: floor-mounted (standard),
wall-mounted, and ceiling-mounted types are available. For wall- and ceiling-mounted
types, contact Adept.
2X Urethane washers
Detail A
Detail B
Shipping jig
Shipping jig
2X M8 Eyebolts
Detail A
Detail B
Remove shipping jig and
insert the cover bolts
2X M6 Hexagon socket head bolts (anti-corrosive)
( Attached with shipping products)
Remove shipping jig and
insert the cover bolts
2X M5 Washers (anti-corrosive)
Use shipping bolts
2X M5 Hexagon socket head bolts (anti-corrosive)
2X Urethane washers
A
B